Walk up user access is available for trained individuals. Waters, acquity hclass smftn hplc replacement parts by. The waters acquity uplc hclass system delivers the flexibility of quaternary solvent blending with the advanced performance of uplc separations. The sqd2 is coupled to a waters acquity hclass uplc for lcms with an esi source. The sqd2 is a lowresolution, single quadrupole mass spectrometer with a range up to 3000 da. This morning i did an injection on vial a8 well plate 48 and i saw the injector going to b8 instead. Acquity, acquity cm30s, acquity h class bio qsm, acquity h class bio smftn, acquity h class qsm, acquity i class bsm, acquity uplc bsm, open architecture uplc, nanoacquity, nanoacquity hdx mgr, nanoacquity uplc bsmasm. The waters 996 pda detector operators guide describes the procedures for installing, maintaining, and troubleshooting the waters 996 pda detector.
The systems holistic design is targeted for routine analysis and method development use and is perfectly suited for running both hplc and uplc applications while still realizing the improved. The waters acquity uplc hclass system provides accurate temperature control across the entire column. The waters acquity uplc hclass system combines chromatographic performance of uplc with the flexibility of quaternary solvent blending. The acquity uplc absorb 10mm cell test solution is used to perform systemlevel performance qualification on an acquity system with tuv or pda detectors, with or without an els detector in line, using the standard 10 mm flow cell configuration. Waters acquity uplc hclass series system manual pdf download. The waters acquity uplc hclass chromatographic system features the quaternary solvent manager and autoblend technology, which. We have 2 waters acquity manuals available for free pdf download.
Acquity uplc hclass plus system the waters acquity uplc hclass plus system delivers the flexibility of quaternary solvent blending with the advanced performance of uplc separations. The low dispersion of the system allows you to maximize chromatographic resolution for the most challenging and complex separations. The waters acquity uplc hclass chromatographic system features the quaternary solvent manager and autoblend technology, which enables you to automatically blend four solvents. Difference between acquity uplc and acquity uplc hclass.
Whether you routinely develop new methods or you perform routine analysis and support large numbers of samples, the acquity uplc hclass system can help you reach your laboratorys. The h class and acquity, differ in the dwell volume of the system, the h class has the larger volume and thus the acquity uplc system has a faster injector cycle time and less of an equilibration time, it is better for ballistic short and steep gradients, but the run times have to be very short uplc hclass system is the only quaternary based liquid chromatographic system that was designed for true uplc performance without compromise. Acquity uplc hclass bio system guide waters corporation. How to troubleshoot sample fluidics high pressure limit. Waters acquity manuals manuals and user guides for waters acquity. Waters acquity uplc the acquity uplc system eliminates significant time and cost per sample from your analytical process while improving the quality of your results. When operating this acquity uplc hclass bio system, follow standard qualitycontrol. Is there a manual that explains the auto blend feature of the acquity uplc hclass.
Jan 28, 2010 the waters acquity uplc h class chromatographic system features the quaternary solvent manager and autoblend technology, which enables you to automatically blend four solvents. Our acquity uplcms sample organizer, sample manager, bsm, pda and sqd is running on windows 7 with masslynx 805. We enable science by offering product choice, services, process excellence and our people make it. It gives an overview of the systems technology and operation. When operating the acquity uplc instruments, follow standard. By outperforming traditional or optimized hplc, this technology allows chromatographers to work at higher efficiencies with a much wider range of linear velocities, flow rates, and. Intended use of the acquity uplc hclass system the waters acquity uplc hclass system is for research use only. Operating the acquity uplc hclass system when operating the acquity uplc hclass system, follow standard qualitycontrol qc procedures and the guidelines presented in this section. Waters acquity uplc hclass system guide attachments waters acquity uplc hclass system guide 2 mb.
The flow path is completely steel free making it more robust against salt build up. Is there a manual that explains the auto blend feature of. Waters acquity uplc hclass series pdf user manuals. Array detector getting started guide for information on plumbing it. Acquity uplc hclass quaternary solvent manager youtube. Agilent 1290 infinity ii lc with isetemulation of the waters. Jul 25, 2011 uplc performance is redefined with the acquity uplc i class system, delivering the highest chromatographic resolution and sensitivity with the lowest lc carr. Uplc performance is redefined with the acquity uplc iclass system, delivering the highest chromatographic resolution and sensitivity with the lowest lc carr. This kit is designed for use by a waters certified engineer or user as part of a performance. Is there a manual that explains the auto blend feature of the acquity uplc h class. To avoid electric shock, do not remove the acquity uplc h class instruments protective panels. W hile pu s h ing t he vang uard p recolu mn in to t he colu mn in let, tur n as semble d column and pre column 1 80. The systems holistic design is targeted for routine analysis and method development use. The acquity arc system is a quaternarybased, modern lc system for scientists working with established methods who are looking for the versatility and robustness required to bridge the gap between hplc and uplc while continuing to support validated assays.
View online or download waters acquity uplc hclass series system manual. Manuals and user guides for waters acquity uplc h class series. Waters acquity uplc h class system guide attachments waters acquity uplc h class system guide 2 mb. February 20 in acquity uplcuhplc our company has recently purchased an h class system that has a flow through needle injector on the sample manager.
Standard operational procedures with rules and guidelines for use of the departmental waters acquity uplcms core facility about this sop this standard operational procedure sop contains a short description of the instruments organization, rules for access to and use of the instrument sample preparation, submitting samples and retrieving data. We have 1 waters acquity uplc h class series manual available for free pdf download. When operating the acquity uplc hclass system, follow standard qualitycontrol. The hplc columns are destroyed if the pressure overrides 2000 psi. Waters, acquity hplc replacement parts by sciencix.
This kit contains the accqtag ultra refill package, manuals, method template, and system accessories. Preventive maintenance pm kits for waters hplc and acquity. To avoid electric shock, do not remove the acquity uplc hclass instruments protective panels. Remove both port 4 and port 3, and port 2 fittings on the inject pod. L, the acquity uplc hclass system delivers the highest resolution of any quaternary lc system in the market. Acquity, acquity hclass bio smftn, acquity hclass smftn, acquity iclass smfl, acquity iclass smftn, acquity mclass smfl, acquity uplc sample mgr, nanoacquity, nanoacquity uplc sample mgr. Acquity uplc hclass system guide waters corporation.
The highest pressure applied for routine analysis is 1400 psi. The sqd2 is coupled to a waters acquity h class uplc for lcms with an esi source. Acquity arc hplcuhplc system from waters corporation. Pdf acquity uplc hclass system guide chetan jagdale.
Achieving true uplc performance requires that system dispersion or extracolumn band spread be matched to the peak widths associated with narrowbore columns packed with sub2. Intended use of the acquity uplc h class system the waters acquity uplc h class system is for research use only. Acquity uplc sample manager problem chromatography forum. The attached user manual covers the atmospheric pressure gas the attached manual describes the acquity uplc glycoprotein beh.
View and download waters acquity system manual online. Acquity uplc system operators guide waters corporation. Acquity uplc hclass system quick reference card miscellaneous 205000343 inline filter holder and six 0. It also describes detector optics and the principles of spectral contrast used in the millennium 32 software for analyzing the data from the pda detector. See how the acquity uplc h class flowthroughneedle sample manager enables familiar hplc operation and uplc performance. Waters asr catalog waters aaa kit for acquity uplc h class. See how the acquity uplc hclass flowthroughneedle sample manager enables familiar hplc operation and uplc performance. Design and function of the i class are based on continuous customer input resulting in improvements in subtwomicron separation that only the originator of the. Attachments waters acquity uplc hclass system instrument specifications 347 kb. The acquity uplc i class system was designed specifically for the rapid pace of laboratories on the cutting edge of research, said art caputo, president of the waters division. The recommended operating ph range for acquity uplc beh columns is 1 to 12 for the c18, c 8 and phenyl chemistries.
Uplc hclass system instrument specifications conquer. The uplc aaa hclass applications kit is intended for acquity uplc hclass users who want to begin performing amino acid analysis aaa. To quantitate data, empower makes it very easy to run many samples and process data. This application note describes the emulation of a ternary gradient on the waters acquity hclass system using the 1290 infinity ii lc with iset for a separation of peptides using a. Acquity uplc system operators guide engineering umass. Is there a manual that explains the auto blend feature of the. System manual waters acquity uplc h class series system manual 92 pages. In addition, the user still has the option to benefit from the wide power range and the superior performance of the 1290 infinity ii lc. I understand how the injector workds for the acquity, but could someone explain how the ftn injector work. The system runs the condition column method and then runs the.
Before starting any operation check that the high pressure limit is set to 1400 psi. Troubleshoot sample fluidics high pressure limit errors on an smftn. Waters 700005119 700005177 289005688 lc mixer assy. Waters acquity overview and maintenance manual 6 pages. Feb 11, 2020 follow the procedure found in the user and maintenance manual, acquity uplc smftn overview and maintenance guide additional information look out for buffer salts around the spring cup, compression spring and inner wall of the wash station.
789 1430 345 24 410 1337 54 380 1396 384 388 684 1344 1128 893 68 20 424 961 601 1522 1108 1128 204 1417 804 587 591 1049 324 1459 1170 249 1347 1189 1039 1355 208 397